Properties
| Name | Type | Description |
|---|---|---|
| resource_id | string | Unique identifier assigned by Solcast when a site is registered. |
| name | string | User-defined name for the PV site (does not need to be unique). |
| latitude | number | Site latitude in decimal degrees (north positive). |
| longitude | number | Site longitude in decimal degrees (east positive). |
| capacity | number | DC system capacity in kilowatts (kW). |
| tilt | number | Panel tilt angle in degrees from horizontal (0 = flat, 90 = vertical). |
| azimuth | number | Panel azimuth in degrees clockwise from north (0/360 = north, 90 = east, 180 = south, 270 = west). |
| install_date | string | Date the PV system was installed (YYYY-MM-DD). |
| ac_capacity | number | AC inverter output capacity in kilowatts (kW). |
| dc_capacity | number | DC array capacity in kilowatts (kW). May differ from capacity if clipping occurs. |
| loss_factor | number | System loss factor as a fraction (0–1). Accounts for wiring, soiling, degradation, and other losses. Typical values 0.75–0.95. |
| tracking_type | string | Panel tracking mechanism type. |
| created_at | string | Timestamp when the site was registered in Solcast. |
| updated_at | string | Timestamp when the site was last modified. |
JSON Schema
{
"$schema": "https://json-schema.org/draft/2020-12/schema",
"$id": "https://raw.githubusercontent.com/api-evangelist/solcast/main/json-schema/solcast-pv-power-site-schema.json",
"title": "PV Power Site",
"description": "A registered Solcast PV power site with full system specifications used with the advanced PV power model.",
"type": "object",
"properties": {
"resource_id": {
"type": "string",
"description": "Unique identifier assigned by Solcast when a site is registered.",
"examples": ["ba75-e17a-7374-95ed"]
},
"name": {
"type": "string",
"description": "User-defined name for the PV site (does not need to be unique).",
"examples": ["Sydney Rooftop Array"]
},
"latitude": {
"type": "number",
"description": "Site latitude in decimal degrees (north positive).",
"minimum": -90,
"maximum": 90,
"examples": [-33.856784]
},
"longitude": {
"type": "number",
"description": "Site longitude in decimal degrees (east positive).",
"minimum": -180,
"maximum": 180,
"examples": [151.215297]
},
"capacity": {
"type": "number",
"description": "DC system capacity in kilowatts (kW).",
"minimum": 0,
"examples": [10.0]
},
"tilt": {
"type": "number",
"description": "Panel tilt angle in degrees from horizontal (0 = flat, 90 = vertical).",
"minimum": 0,
"maximum": 90,
"examples": [25]
},
"azimuth": {
"type": "number",
"description": "Panel azimuth in degrees clockwise from north (0/360 = north, 90 = east, 180 = south, 270 = west).",
"minimum": 0,
"maximum": 360,
"examples": [180]
},
"install_date": {
"type": "string",
"format": "date",
"description": "Date the PV system was installed (YYYY-MM-DD).",
"examples": ["2020-06-01"]
},
"ac_capacity": {
"type": "number",
"description": "AC inverter output capacity in kilowatts (kW).",
"minimum": 0
},
"dc_capacity": {
"type": "number",
"description": "DC array capacity in kilowatts (kW). May differ from capacity if clipping occurs.",
"minimum": 0
},
"loss_factor": {
"type": "number",
"description": "System loss factor as a fraction (0–1). Accounts for wiring, soiling, degradation, and other losses. Typical values 0.75–0.95.",
"minimum": 0,
"maximum": 1,
"examples": [0.9]
},
"tracking_type": {
"type": "string",
"description": "Panel tracking mechanism type.",
"enum": ["fixed", "horizontal_single_axis", "vertical_single_axis", "two_axis"],
"examples": ["fixed"]
},
"created_at": {
"type": "string",
"format": "date-time",
"description": "Timestamp when the site was registered in Solcast."
},
"updated_at": {
"type": "string",
"format": "date-time",
"description": "Timestamp when the site was last modified."
}
},
"required": ["resource_id", "name", "latitude", "longitude"],
"examples": [
{
"resource_id": "ba75-e17a-7374-95ed",
"name": "Sydney Rooftop Array",
"latitude": -33.856784,
"longitude": 151.215297,
"capacity": 10.0,
"tilt": 25,
"azimuth": 180,
"install_date": "2020-06-01",
"loss_factor": 0.9,
"tracking_type": "fixed",
"created_at": "2020-06-15T10:00:00.0000000Z",
"updated_at": "2023-01-10T09:00:00.0000000Z"
}
]
}