SolarEdge · Schema
SolarEdge Inverter Telemetry
Technical telemetry data from a SolarEdge inverter
SolarEnergyMonitoringPVInverterRenewable EnergyIoT
Properties
| Name | Type | Description |
|---|---|---|
| date | string | Measurement timestamp |
| totalActivePower | number | Total active power output in W |
| dcVoltage | number | DC input voltage in V |
| groundFaultResistance | number | Ground fault resistance in kOhm |
| powerLimit | number | Active power limit as a percentage of rated capacity |
| totalEnergy | number | Lifetime total energy production in Wh |
| temperature | number | Inverter heatsink temperature in Celsius |
| inverterMode | string | Inverter operating mode string |
| operationMode | integer | Numeric operation mode code |
| L1Data | object | |
| L2Data | object | |
| L3Data | object |
JSON Schema
{
"$schema": "https://json-schema.org/draft/2020-12/schema",
"$id": "https://raw.githubusercontent.com/api-evangelist/solar-edge/main/json-schema/solar-edge-inverter.json",
"title": "SolarEdge Inverter Telemetry",
"description": "Technical telemetry data from a SolarEdge inverter",
"type": "object",
"properties": {
"date": {
"type": "string",
"description": "Measurement timestamp"
},
"totalActivePower": {
"type": "number",
"description": "Total active power output in W"
},
"dcVoltage": {
"type": "number",
"description": "DC input voltage in V"
},
"groundFaultResistance": {
"type": "number",
"description": "Ground fault resistance in kOhm"
},
"powerLimit": {
"type": "number",
"description": "Active power limit as a percentage of rated capacity"
},
"totalEnergy": {
"type": "number",
"description": "Lifetime total energy production in Wh"
},
"temperature": {
"type": "number",
"description": "Inverter heatsink temperature in Celsius"
},
"inverterMode": {
"type": "string",
"description": "Inverter operating mode string"
},
"operationMode": {
"type": "integer",
"description": "Numeric operation mode code"
},
"L1Data": { "$ref": "#/$defs/PhaseData" },
"L2Data": { "$ref": "#/$defs/PhaseData" },
"L3Data": { "$ref": "#/$defs/PhaseData" }
},
"$defs": {
"PhaseData": {
"type": "object",
"description": "Per-phase AC electrical measurements",
"properties": {
"acCurrent": {
"type": "number",
"description": "AC current in A"
},
"acVoltage": {
"type": "number",
"description": "AC voltage in V"
},
"acFrequency": {
"type": "number",
"description": "AC grid frequency in Hz"
},
"apparentPower": {
"type": "number",
"description": "Apparent power in VA"
},
"activePower": {
"type": "number",
"description": "Active (real) power in W"
},
"reactivePower": {
"type": "number",
"description": "Reactive power in VAR"
},
"cosPhi": {
"type": "number",
"minimum": -1,
"maximum": 1,
"description": "Power factor (cosine phi)"
}
}
}
}
}